Search results for "Synthetic inertia"
showing 8 items of 8 documents
Synthetic Inertia Impact on Inter-Area Oscillations of the Continental Europe Power System
2020
The overall kinetic energy reduction due to increasing share of converter-interfaced generation (CIG) has been investigated so far by several works for systems of different types and sizes. The so called synthetic inertia is one of the most common and reviewed solutions to the issue of system inertia reduction. The paper investigates the effects of synthetic inertia as frequency service provided by the CIG sources for the Continental Europe (CE) synchronous area using a detailed large scale dynamic model. The model - provided in the basic form by the System Protection & Dynamics (SP&D) group of the ENTSOE - is properly developed substituting a determined amount of synchronous machin…
Impact of RES penetration on the frequency dynamics of the 500 kV vietnamese power system
2019
The increase of renewable energy sources (RES) typically operating as converter-interfaced generation (CIG) is progressively causing a significant change of power systems operation paradigm. The reduction of the overall available kinetic energy and the consequent impact on the dynamic response of the system is a relevant issue currently under investigation in academic and industrial scopes. The work analyzes the impact of different CIG penetration in the three areas of the 500 kV Vietnamese power system, North, Center and South. The system is modified substituting conventional synchronous generation with converter-interfaced generation. The models of power converters and corresponding contr…
Grid Stability Improvement Using Synthetic Inertia by Battery Energy Storage Systems in Small Islands
2022
In this paper, the synthetic inertia need of the small island of Pantelleria in the Mediterranean Sea is assessed. Firstly, the optimal renewable energy mix able to minimize the Levelized Cost of Energy for the generation system of the island is evaluated, considering the yearly load demand and the characteristics of the local natural resources. The optimal energy mix introduces in the island a quota of power generation with static power converters interfaced to the grid that could jeopardize the security of the system if not suitably controlled. Therefore, the inherent inertial response of the diesel generators of the system is calculated hour by hour for each month of one year, considerin…
Inertial response of isolated power networks with wind power plants
2019
The constant increase of power generation provided by renewable energy source (RES) power plants is causing a progressive reduction of the overall inertia of the power systems. Especially in the case of small, isolated power networks, the replacement of conventional generation plants with RES power plants can affect significantly the frequency response of the system. The critical low-inertia conditions can be improved by the introduction of specific additional controls to the RES power converters. These control schemes are known as “synthetic inertia” or “virtual inertia” controls. The paper analyzes the impact of a derivative-based inertial control on a small, isolated power system, with a…
Analysis of a Fast Reserve Unit Behaviour with Additional Modular Synthetic Inertia Control
2021
The paper presents the results of a theoretical study on the behaviour of a battery storage system operated as a Fast Reserve Unit and equipped with additional synthetic inertia control. The Fast Reserve Unit is assumed connected to the transmission system of Sicily, operated as an isolated grid in order to show more clearly the effect of the Fast Reserve Unit intervention during a power imbalance. The unit is controlled also to provide synthetic inertia with a conventional control scheme and with a new scheme proposed by the authors and named “Modular Synthetic Inertia”. The latter has been conceived for offering a modular response as a function of the Rate of Change of Frequency, to avoid…
An original control strategy of storage systems for the frequency stability of autonomous grids with renewable power generation
2021
This work examines the operation of the autonomous power system of a geographical island assuming the integration of significant generation shares from renewable energy sources and the installation of the required storage systems. The frequency stability of the system is investigated considering different operating conditions, in terms of load demand and renewable power generation. The main focus of the work is an original control strategy specifically designed for power converters interfacing storage units to the grid. The proposed strategy is based on an extended frequency droop control, which selects specific droop settings depending on the operating mode—charge or discharge—of the stora…
Primary Frequency Control in the Power System of Continental Europe including the Dynamics of the HVDC Link France-Great Britain
2020
The paper presents a study of primary frequency control within the power system of Continental Europe (CE) including the dynamics of the high voltage direct current (HVDC) link between France and Great Britain (GB). The large-scale dynamic model of the CE system originally provided by ENTSO-E is extended with a more detailed representation of the whole HVDC interconnection. The dynamics of the GB synchronous area is also considered in the analysis, implementing a system equivalent suitable for primary frequency control studies. The opportunity of frequency containment reserve exchange between the two areas through the link is also investigated, considering supplementary frequency controls w…
A simulation study for assessing the impact of energy storage systems for Fast Reserve with additional synthetic inertia control on the Continental E…
2022
This article shows the results of a simulation study on the application of battery storage systems for providing fast frequency regulation (the so-named Fast Reserve) with additional synthetic inertia control. The aim of the study is to assess the impact of the extension of the regulation provided by the FRUs to all the Continental Europe synchronous grid, with the same power proportions of the first Italian FRU auction. The simulations are conducted in two different scenarios: a base one related to 2020 and a future one related to 2040 and based on ENTSO-E projections for load and generation. The results show that, for the reference incident of 3000 MW, the frequency quality parameters in …